bandera
Hogar

Cámara de prueba de temperatura sin cita previa

Cámara de prueba de temperatura sin cita previa

  • Energy-Saving Environmental Test Chamber: Safeguard Your Long-Term Product Costs
    Dec 01, 2025
    For enterprises in manufacturing, electronic technology, and related industries, product reliability testing is a critical quality assurance link. However, the operational costs of environmental test chambers—core testing equipment—are often overlooked. Many businesses focus solely on testing precision during procurement, only to be troubled by high energy bills in long-term use. Our energy-saving environmental test chamber effectively resolves the conflict between "accurate testing" and "cost control," providing comprehensive support for product lifecycle cost management. Core Energy-Saving Feature: Intelligent Refrigeration System Regulation As the primary energy-consuming component of environmental test chambers, the energy regulation technology of the refrigeration system directly determines the equipment’s energy efficiency. On the premise of meeting core technical indicators, this test chamber innovatively integrates multiple energy adjustment measures to achieve intelligent dynamic control of refrigeration capacity. The system precisely regulates evaporation temperature via the controller and links it with a hot gas bypass energy adjustment mechanism, matching refrigeration demand in real time based on the required cooling rate and target temperature range. When approaching the set low temperature, the system automatically reduces refrigeration capacity to avoid temperature overshoot—a common issue in traditional models—ensuring test stability. During the constant temperature phase, it abandons the energy-intensive "hot-cold balance" mode, optimizing energy utilization at the source. Verified in real operating conditions, the energy-saving effect reaches up to 30%, significantly reducing long-term operational costs, especially for enterprises requiring 24/7 continuous operation. Precision & Energy Efficiency: Optimized Heating System Power Control Refined control of the heating system further enhances the equipment’s energy-saving advantages and temperature control precision. The system adopts a synergistic control scheme of temperature controllers and thyristors: the temperature controller collects real-time temperature signals and issues control commands, while thyristors precisely adjust the heater’s power output. When the temperature is far below the set value, thyristors deliver full power for rapid heating. As the temperature gradually approaches the set value, the output power decreases incrementally; once the target temperature is reached, power output stops immediately. This on-demand power distribution mode eliminates energy waste and ensures precise temperature control, providing a stable and reliable temperature environment for tests. For example: When the internal temperature is significantly lower than the set value, thyristors operate at full power, and the heater runs at maximum load to ensure rapid temperature rise. As the temperature nears the target, the thyristor’s output power gradually decreases. Once the target temperature is achieved, the thyristor stops power output immediately, and the heater enters standby mode. This "on-demand power supply" mode eliminates the drawback of "frequent start-stop" in traditional heating systems—avoiding ineffective energy consumption while greatly improving temperature control precision, making it particularly suitable for test scenarios requiring high temperature stability. Dual-System Synergy: Safeguard Enterprise Costs From the refrigeration system’s intelligent energy adjustment to the heating system’s precision power control, our environmental test chamber centers on dual-system collaborative energy-saving technology. While ensuring accurate test data, it maximizes energy cost reduction. Choosing our test chamber not only guarantees product testing quality but also enables scientific management of enterprise operational costs, providing peace of mind throughout your product R&D and production processes. In addition, if your enterprise is seeking a cost-effective environmental test chamber or struggling with high energy consumption from existing equipment, we recommend focusing on our energy-saving model. Let professional equipment protect your product quality while reducing costs and enhancing efficiency for your business.
    LEER MÁS
  • Got Your Temperature Test Chamber? Here’s What You Must Do Next!
    Nov 28, 2025
    I. Receipt Inspection  1. Physical Verification Confirm equipment model, specifications, and serial number match the contract/packing list to avoid wrong delivery. Inspect the cabinet, door, and control panel for transportation damage (dents, deformation) and ensure pipelines/wiring are intact without loosening. 2. Accessory & Document Check Required accessories: Power cord, sample shelves, sealing rings, wrenches, and other tools (verify against the packing list). Technical documents: Operation/maintenance manual, calibration certificate, warranty card, and qualification certificate (all mandatory for after-sales service). 3. Abnormal Handling In case of damage or missing items: Immediately take photos (overall equipment, damaged details, packing list), notify the supplier within 24 hours to submit a claim, and sign the "Acceptance Objection Form" for documentation. II. Installation & Deployment (Compliant Installation Ensures Performance) 1. Environment Requirements (Must Meet the Following) Floor: Flat and sturdy, with load-bearing capacity ≥1.2 times the equipment weight (to avoid test errors caused by vibration). Space: ≥30cm ventilation gap around the cabinet; keep away from heat sources, water sources, dust, and strong electromagnetic interference. Power supply: Match the rated voltage (e.g., 380V three-phase five-wire/220V single-phase), grounding resistance ≤4Ω, and equip an independent air switch (power ≥1.2 times the equipment's rated power). Environment: Room temperature 15-35℃, humidity ≤85%RH (no condensation); water-cooled models require pre-connected cooling water circuits meeting specifications. 2. Basic Installation Steps Level the equipment: Adjust anchor bolts and use a level to confirm horizontal alignment (to prevent uneven stress on the refrigeration system). Wiring inspection: Connect the power supply per the manual and ensure correct neutral/grounding connections (a common cause of electrical failures). Consumable check: Confirm refrigerant and lubricating oil (if applicable) are properly filled with no leakage. III. Commissioning (Core: Verify Performance Compliance) 1. First Startup Procedure (1) Recheck power/pipeline connections before power-on; switch on after confirmation. (2)Panel self-test: Ensure the display shows no error codes and buttons/indicators function normally. (3)No-load operation (2-4 hours): Set a common temperature range (e.g., -40℃~85℃) and monitor temperature fluctuation ≤±0.5℃ (meets industrial standards). Check door sealing (no obvious air leakage), operating noise ≤75dB, and normal start/stop of refrigeration/heating systems. 2. Load Verification (Simulate Actual Usage) Place a load equivalent to the test sample (weight/volume ≤80% of the equipment's rated load) without blocking air ducts. Set the target temperature and holding time; record if the heating/cooling rate meets technical parameters (e.g., -40℃~85℃ heating time ≤60 minutes). Alarm test: Simulate power failure, over-temperature, or door-open timeout to confirm timely alarm response (audio-visual alarm + shutdown protection). IV. Emergency Handling & After-Sales Coordination 1. Common Fault Resolution Error codes: Refer to the "Troubleshooting" section in the manual (e.g., E1=Over-temperature, E2=Power abnormality). Sudden failures: (e.g., electric leakage, abnormal noise, refrigeration failure) Immediately cut off power, stop use, and contact the supplier's technical support (do not disassemble independently). 2. After-Sales Support Retain the supplier's after-sales contact (phone + email) and confirm the warranty period (usually 1 year for the whole machine). Maintenance records: Request a "Maintenance Report" after each service and file it for future tracing.
    LEER MÁS
  • La introducción de la cámara de prueba de temperatura sin cita previa
    Feb 24, 2025
    Cámara de prueba de temperatura sin cita previa es un gran laboratorio que admite que el operador camina en él, utilizado principalmente para las pruebas ambientales. Se usa comúnmente para probar grandes piezas, productos semi-terminados y productos terminados para simular temperaturas ambientales del mundo real, y se usa ampliamente en industrias como ingeniería eléctrica, electrodomésticos, instrumentos, electrónica, seguridad, comunicación, sensores, automatización, automatización, automatización , control industrial, maquinaria de precisión, etc. La cámara de prueba de temperatura sin cita previa está equipada con un orificio de prueba de 50 mm con un enchufe en el costado de la caja. El material del enchufe es un caucho de silicona bajo en espuma, que puede soportar temperaturas altas y bajas y tiene un efecto de aislamiento. El calentador adopta un calentador eléctrico de alambre de cromo de níquel de porcelana, que tiene baja inercia térmica y una larga vida útil. El instrumento genera una señal PID del ciclo de trabajo de pulso controlable, que está controlada por un relé de estado sólido para que el control sea más suave y confiable. Rendimiento y características de la cámara de prueba de temperatura sin cita previa: 1. Tiene un rango de control de temperatura y humedad extremadamente amplio, que puede satisfacer varias necesidades para los usuarios. Al adoptar un método único de control de temperatura y humedad equilibrados, se puede lograr un entorno de temperatura y humedad seguro y preciso. Tiene un rendimiento de calentamiento y humidificación estable y equilibrado, puede lograr un control de temperatura y humedad de alta precisión. 2. Equipado con reguladores de temperatura inteligentes, la temperatura y la humedad se muestran utilizando la pantalla digital LED. La cámara de prueba de calor húmedo de alta temperatura y baja temperatura se puede equipar opcionalmente con una grabadora de temperatura y humedad. 3. Selección automática del circuito de refrigeración, el dispositivo de control automático tiene el rendimiento de seleccionar y operar automáticamente al circuito de refrigeración de acuerdo con el valor establecido de la temperatura, realizando el inicio directo de la máquina de refrigeración y el enfriamiento directo en condiciones de alta temperatura. 4. La puerta interior está equipada con una gran ventana de observación, que facilita la observación del estado experimental de las muestras de prueba. 5. Equipado con dispositivos avanzados de seguridad y protección: interruptor de circuito de corriente residual, protector de sobre temperatura, protector de pérdida de fase y protector de corte de agua. Podemos al cliente cámaras de prueba de alta temperatura a baja temperatura, cámaras de prueba de baja temperatura, cámaras de prueba de temperatura constante y humedad, cámaras de prueba de calor húmedo de temperatura alta y baja, cámaras de prueba de calor húmeda alterna y baja temperatura, cámaras de prueba de corrosión por pulverización de sal. Las cámaras de prueba anteriores se pueden personalizar de acuerdo con sus requisitos. Por lo tanto, la cámara de prueba de temperatura sin cita previa es adecuada para empresas con alta demanda de pruebas ambientales y espacio operativo.
    LEER MÁS

dejar un mensaje

dejar un mensaje
Si está interesado en nuestros productos y desea conocer más detalles, deje un mensaje aquí, le responderemos lo antes posible.
entregar

Hogar

Productos

Whatsapp

contáctanos